-40%

PROVA-903 Dual Channels Digital Multimeter Continuity Diode Freque Tester Meter

$ 142.56

Availability: 79 in stock
  • Manufacturer Part Number: PROVA-903
  • Type: Digital Multimeter
  • UPC: 609636908041
  • MPN: PROVA-903
  • Condition: New
  • Country of Manufacture: China
  • Brand: Unbranded
  • Warranty: 1 Year

    Description

    PROVA-903 Dual Channels Digital Multimeter Continuity Diode Freque Tester Meter
    Detail
    I.Introduction:
    The DMM to replace your bench-top one
    0.02% DC and 0.1% AC basic accuracy
    60,000 counts resolution
    200KHz (max.) bandwidth
    True RMS with fast ACV/ACA response
    Dual channels measurement similar to a dual channels DSO (V+V, V+A)
    RS-232C ASCII interface
    Data logging (model
    903
    with 10,708 records for both channels)
    Capacitance measurement
    Free software (
    901,903
    )
    1/3 the cost
    II.Specification:
    The following accuracy is specified for one single channel (channel 1 or channel 2). If dual channels are used at the same time, additional % of accuracy should be added to the listed accuracy. Please refer to the supplemental dual channels specification. The following accuracy is also specified for the ZEROED (relative) value. The accuracy is given as ±% of reading ± number of least significant digits.
    Continuity
    :
    (
    , open voltage 3V approx.)
    Range
    Resolution
    Beeper
    Overload Protection
    999.99 Ω
    0.01 Ω
    < 40 Ω ( approx )
    AC 1000V
    Diode Test :
    (open voltage 3V approx.)
    Range
    Resolution
    ShortCircuit Current
    Overload Protection
    3.0000V
    0.0001V
    0.8 mA typical
    AC 1000V
    Frequency :
    Range ( Auto )
    Resolution
    Accuracy
    Overload Protection
    1Hz - 200KHz( sine wave )
    0.0001Hz -100Hz
    ±0.02%±4dgts
    AC 1000V
    1Hz -2MHz (TTL)
    0.0001Hz - 0.0001MHz
    ±0.005%±4dgts
    AC 1000V
    Duty Cycle
    :
    (%, TTL, 1Hz – 600KHz )
    Range
    Resolution
    Accuracy
    Overload Protection
    0.001% - 9.999%
    0.001%
    ±30d/KHz±30dgts
    AC 1000V
    10.00% - 100.00%
    0.01%
    ±3d/KHz±3dgts
    AC 1000V
    Resistance
    :
    ( Ω )
    Range
    Resolution
    Accuracy
    Overload Protection
    999.99 Ω
    0.01 Ω
    ±0.15%±8dgts
    AC 1000V
    9.9999K Ω
    0.0001K Ω
    ±0.09%±3dgts
    AC 1000V
    99.999K Ω
    0.001K Ω
    ±0.09%±3dgts
    AC 1000V
    999.99K Ω
    0.01K Ω
    ±0.09%±3dgts
    AC 1000V
    9.9999M Ω
    0.0001M Ω
    ±0.2%±6dgts
    AC 1000V
    40.000M Ω
    0.001M Ω
    ±1%±6dgts
    AC 1000V
    Capacitance
    :
    (
    , auto range , and for film capacitor or better)
    Range
    Resolution
    Accuracy 1
    60.00nF
    0.01nF
    ±0.8%±5dgts
    600.0nF
    0.1n F
    ±1.5%±5dgts
    6.000 μ F
    0.001 μ F
    ±1.5 %±5dgts
    60.00 μ F
    0.01 μ F
    ±2.0%±5dgts
    600.0 μ F
    0.1 μ F
    ±3.5%±5dgts
    DC Voltage
    :
    (Input Impedance: 10M )
    Range
    Resolution
    Accuracy
    Overload Protection
    60.000mV
    0.001mV
    ±0.1%±5dgts 1
    DC 1000V
    600.00mV
    0.01mV
    ±0.02%±3dgts
    DC 1000V
    6.0000V
    0.0001V
    ±0.02%±3dgts
    DC 1000V
    60.000V
    0.001V
    ±0.02%±3dgts
    DC 1000V
    600.00V
    0.01V
    ±0.02%±3dgts
    DC 1000V
    1000.0V
    0.1V
    ±0.04%±3dgts
    DC 1000V
    DC Current
    :
    (10A terminal is protected by a 10A fast blown, high energy fuse, and the terminal of μ A and mA is protected by 1A fast blown, high energy fuse )
    Range
    Resolution
    Accuracy
    600.00 μ A
    0.01 μ A
    ±0.2%±10dgts
    6000.0 μ A
    0.1 μ A
    ±0.1%±10dgts
    60.000mA
    0.001mA
    ±0.2%±10dgts
    600.00mA
    0.01mA
    ±0.1%±10dgts
    1.0000A
    0.0001A
    ±0.1%±10dgts
    10.000A 1
    0.001A
    ±0.3%±10dgts
    AC Current
    :
    (The accuracy is specified for a single channel for 5%-100% of range for 45Hz – 20KHz, True RMS, 10A terminal is protected by a 10A fast blown, high energy fuse, and the terminal of μ A and mA is protected by 1A fast blown, high energy fuse )
    Range (ACA)
    Resolution
    Accuracy (50/60Hz)
    Accuracy (45Hz - 1KHz)
    600.00 μ A
    0.01m A
    ±0.3%±20dgts
    ±0.4%±20dgts
    6000.0 μ A
    0.1m A
    ±0.3%±20dgts
    ±0.4%±20dgts
    60.000mA
    0.001mA
    ±0.3%±20dgts
    ±0.4%±20dgts
    600.00mA
    0.01mA
    ±0.3%±20dgts
    ±0.4%±20dgts
    1.0000A
    0.0001A
    ±0.3%±20dgts
    ±0.4%±20dgts
    10.000A 1
    0.001A
    ±0.5%±20dgts
    ±0.4%±20dgts
    Range
    (ACA)
    Accuracy
    (20Hz - 45Hz)
    Accuracy
    (1KHz – 10KHz)
    Accuracy
    (10KHz – 20KHz)
    600.00 μ A
    ±1%±20dgts
    ±2%±20dgts
    ±1%±20dgts
    6000.0 μ A
    ±1%±20dgts
    ±2%±20dgts
    ±1%±20dgts
    60.000mA
    ±1%±20dgts
    ±0.5%±20dgts
    ±1%±20dgts
    600.00mA
    ±1%±20dgts
    ±0.5%±20dgts
    ±1%±20dgts
    1.0000A
    ±1%±20dgts
    ±1.5%±20dgts
    Not Specified
    10.000A 1
    ±2%±20dgts
    ±1.5%±20dgts
    Not Specified
    AC Voltage
    :
    The accuracy of ACV or AC mV is specified for 5%-100% of range from 20Hz – 10KHz, average sensing. Input Impedance is 10M , and overloaded protection is AC 1000V for all range. Accuracy is also specified for single channel (channel 1 or channel 2). If dual channels measurements are performed, additional specification of accuracy will be introduced. Please refer to the supplemental dual channels specification. Due to the wide bandwidth, the reading might not be zero when no inputs present. But the residual reading does not affect the listed accuracy. If the AC reading is less than 100 least significant counts, it is set to zero by the unit.
    Range
    (ACV)
    Resolution
    Accuracy
    (50/60Hz)
    Accuracy
    (45Hz - 1KHz)
    Accuracy
    (20Hz - 45Hz)
    60.000mV
    0.001mV
    ±0.1%±20dgts
    ±0.3%±20dgts
    ±0.8%±25dgts
    600.00mV
    0.01mV
    ±0.1%±20dgts
    ±0.3%±20dgts
    ±0.8%±25dgts
    6.0000V
    0.0001V
    ±0.1%±20dgts
    ±0.3%±20dgts
    ±0.8%±25dgts
    60.000V
    0.001V
    ±0.1%±20dgts
    ±0.3%±20dgts
    ±0.8%±25dgts
    600.00V
    0.01V
    ±0.1%±20dgts
    ±0.5%±20dgts
    ±0.8%±25dgts
    1000.0V
    (0–400V)
    0.1V
    ±0.1%±20dgts
    ±2%±30dgts
    ±0.8%±25dgts
    1000.0V
    (400-1000V)
    0.1V
    ±0.1%±20dgts
    (45Hz – 400Hz)
    ±2%±30dgts
    ±0.8%±25dgts
    Range
    (ACV)
    Accuracy
    1KHz–10KHz)
    Accuracy
    (10KHz–20KHz)
    Accuracy
    (20KHz-50KHz)
    Accuracy
    (50KHz-100KHz)
    Accuracy
    (100kHz-200KHz)
    60.000mV
    ±2%±20dgts
    ±2.5%±20dgts
    ±4%±40dgts
    ±4%±40dgts
    Not Specified
    600.00mV
    ±1%±20dgts
    ±2.5%±20dgts
    ±2%±40dgts
    ±2%±40dgts
    ±2%±40dgts
    6.0000V
    ±1%±20dgts
    ±2.0%±20dgts
    ±2%±40dgts
    ±2%±40dgts
    ±2%±40dgts
    60.000V
    ±1%±20dgts
    ±2.0%±20dgts
    ±4%±40dgts
    Not Specified
    Not Specified
    600.00V
    (0-400V)
    ±5%±20dgts
    Not Specified
    Not Specified
    Not Specified
    Not Specified
    600.00V
    (400-600V)
    Not Specified
    Not Specified
    Not Specified
    Not Specified
    Not Specified
    1000.0V
    (0-400V)
    ±2%±40dgts
    Not Specified
    Not Specified
    Not Specified
    Not Specified
    1000.0V
    (400-1000V)
    Not Specified
    Not Specified
    Not Specified
    Not Specified
    Not Specified
    Supplemental Dual Channels Specification (DC – 400Hz):
    The following accuracy should be added to all the listed accuracy if dual channels measurements are performed.
    ACV (Ch2)
    DCV (Ch2)
    ACA (Ch2)
    DCA (Ch2)
    ACV (Ch1)
    ±1%±( V1 - V2 ) 200 PPM (Ch1, Ch2)
    ±0.5%±(V1 - V2) * 20 PPM (Ch1, Ch2)
    ±0.1 μ A / V( μ A,Ch2)
    ±1 μ A / V (mA,Ch2)
    ±0.2mA / V (A, Ch2)
    ±2mV / A (mV, Ch1)
    ± 5mV / A (V, Ch1)
    ±0.25% (Ch1, Ch2)
    DCV (Ch1)
    ±0.5%±(V1 - V2) * 20 PPM (Ch1, Ch2)
    ±0.25% (Ch1,Ch2
    ±0.25% (Ch1, Ch2)
    ±0.25% (Ch1, Ch2)
    General Specification
    Battery Type
    9V
    Display
    5 + 5 digits LCD with 30 segments bar graph
    Range Selection
    auto and manual
    Overload Indication
    OL
    Power Consumption
    6 mA ( approx )
    Low battery Indication
    Operating Temperature
    -10 C to 50 C
    Operating Humidity
    less than 85% relative
    Altitude
    up to 2000M
    Storage Temperature
    -20 C to 60 C
    Storage Humidity
    less than 75% relative
    Dimension
    207mm(L) x 101mm (W) x 47mm (H)8.15" (L) x 4" (W) x 1.85" (H)
    Weight
    430g / 15.2oz (battery included)
    Accessories
    Users manual x 1
    RS-232C interface cable
    Duty
    For International Buyers
    Import duties, taxes and charges are not included in the item price or shipping charges. These charges are the buyer's responsibility.
    Please check with your country's customs office to determine what these additional costs will be prior to bidding/buying.
    Shipping Policy
    Payment Method
    Returns Policy
    About Feedback
    Shipping Policy
    ● Expedited Shipping(FedEx/DHL/TNT/UPS): To USA 3-6 Workdays ,To other countries 3-8 Workdays
    ● Economy Shipping(Post/Airmail/DHL e-commerce): To USA 7-12 Workdays ,To United Kingdom & Australia 20-35 Workdays , To other countries 20-50 Workdays
    ● This is normal condition,but sometimes int'l delivery is highly depended on the courier company and local customs/duties
    ● We only accept Paypal payment.We are not able to ship to PO Boxes or APO/FPO addresses
    ● Please make sure to provide us with correct , precise and detailed shipping Address
    ● And it would be better to leave us correct phone number,so the delivery man can get in touch with you easily when your package arrive .And we wouldn't use your phone number for other purpose.
    ● Order will be shipped out within 1 to 3 business days upon payment received or cleared.
    ● If you don't receive package over 30 business workdays , please notify us.
    Payment Method
    ● PayPal payment accepted only.
    ● Items will be shipped to your eBay address. Please make sure it is correct.
    ● Payment must be received 4 days after auction ended.
    Returns Policy
    ● Customer satisfaction is our top goal. We believe our items are so outstanding. All products are quality checked. They are new and in good condition when shipped to our customers. We are convinced you will be happy with your Purchase.
    ● If product is defective or damage upon arrival, or wrong product shipped, please contact us immediately. Returns accepted within 30 workdays of delivery date and item must be in original new condition, not worn or altered in any way with attached tags & wrap. Otherwise deal is final. Return shipping must be paid by buyer.
    ● Please contact us first if you have any problems/questions/concerns. We will be happy to resolve any issues you may have in a cordial and friendly manner.
    About Feedback
    ● When you satisfied with our product and services please leave us positive feedback.
    ● If a problem occurs, just contact us using the " Ask the seller a question" link on eBay.
    ● We appreciate your Postive Feedback, and will do the same in return. DO NOT leave negative feedback without first communication with us. Please allow max 3 business days for us to response .
    Reviews