PROVA-903 Dual Channels Digital Multimeter Continuity Diode Freque Tester MeterDetail
I.Introduction:
The DMM to replace your bench-top one
0.02% DC and 0.1% AC basic accuracy
60,000 counts resolution
200KHz (max.) bandwidth
True RMS with fast ACV/ACA response
Dual channels measurement similar to a dual channels DSO (V+V, V+A)
RS-232C ASCII interface
Data logging (model
903
with 10,708 records for both channels)
Capacitance measurement
Free software (
901,903
)
1/3 the cost
II.Specification:
The following accuracy is specified for one single channel (channel 1 or channel 2). If dual channels are used at the same time, additional % of accuracy should be added to the listed accuracy. Please refer to the supplemental dual channels specification. The following accuracy is also specified for the ZEROED (relative) value. The accuracy is given as ±% of reading ± number of least significant digits.
Continuity
:
(
, open voltage 3V approx.)
Range
Resolution
Beeper
Overload Protection
999.99 Ω
0.01 Ω
< 40 Ω ( approx )
AC 1000V
Diode Test :
(open voltage 3V approx.)
Range
Resolution
ShortCircuit Current
Overload Protection
3.0000V
0.0001V
0.8 mA typical
AC 1000V
Frequency :
Range ( Auto )
Resolution
Accuracy
Overload Protection
1Hz - 200KHz( sine wave )
0.0001Hz -100Hz
±0.02%±4dgts
AC 1000V
1Hz -2MHz (TTL)
0.0001Hz - 0.0001MHz
±0.005%±4dgts
AC 1000V
Duty Cycle
:
(%, TTL, 1Hz – 600KHz )
Range
Resolution
Accuracy
Overload Protection
0.001% - 9.999%
0.001%
±30d/KHz±30dgts
AC 1000V
10.00% - 100.00%
0.01%
±3d/KHz±3dgts
AC 1000V
Resistance
:
( Ω )
Range
Resolution
Accuracy
Overload Protection
999.99 Ω
0.01 Ω
±0.15%±8dgts
AC 1000V
9.9999K Ω
0.0001K Ω
±0.09%±3dgts
AC 1000V
99.999K Ω
0.001K Ω
±0.09%±3dgts
AC 1000V
999.99K Ω
0.01K Ω
±0.09%±3dgts
AC 1000V
9.9999M Ω
0.0001M Ω
±0.2%±6dgts
AC 1000V
40.000M Ω
0.001M Ω
±1%±6dgts
AC 1000V
Capacitance
:
(
, auto range , and for film capacitor or better)
Range
Resolution
Accuracy 1
60.00nF
0.01nF
±0.8%±5dgts
600.0nF
0.1n F
±1.5%±5dgts
6.000 μ F
0.001 μ F
±1.5 %±5dgts
60.00 μ F
0.01 μ F
±2.0%±5dgts
600.0 μ F
0.1 μ F
±3.5%±5dgts
DC Voltage
:
(Input Impedance: 10M )
Range
Resolution
Accuracy
Overload Protection
60.000mV
0.001mV
±0.1%±5dgts 1
DC 1000V
600.00mV
0.01mV
±0.02%±3dgts
DC 1000V
6.0000V
0.0001V
±0.02%±3dgts
DC 1000V
60.000V
0.001V
±0.02%±3dgts
DC 1000V
600.00V
0.01V
±0.02%±3dgts
DC 1000V
1000.0V
0.1V
±0.04%±3dgts
DC 1000V
DC Current
:
(10A terminal is protected by a 10A fast blown, high energy fuse, and the terminal of μ A and mA is protected by 1A fast blown, high energy fuse )
Range
Resolution
Accuracy
600.00 μ A
0.01 μ A
±0.2%±10dgts
6000.0 μ A
0.1 μ A
±0.1%±10dgts
60.000mA
0.001mA
±0.2%±10dgts
600.00mA
0.01mA
±0.1%±10dgts
1.0000A
0.0001A
±0.1%±10dgts
10.000A 1
0.001A
±0.3%±10dgts
AC Current
:
(The accuracy is specified for a single channel for 5%-100% of range for 45Hz – 20KHz, True RMS, 10A terminal is protected by a 10A fast blown, high energy fuse, and the terminal of μ A and mA is protected by 1A fast blown, high energy fuse )
Range (ACA)
Resolution
Accuracy (50/60Hz)
Accuracy (45Hz - 1KHz)
600.00 μ A
0.01m A
±0.3%±20dgts
±0.4%±20dgts
6000.0 μ A
0.1m A
±0.3%±20dgts
±0.4%±20dgts
60.000mA
0.001mA
±0.3%±20dgts
±0.4%±20dgts
600.00mA
0.01mA
±0.3%±20dgts
±0.4%±20dgts
1.0000A
0.0001A
±0.3%±20dgts
±0.4%±20dgts
10.000A 1
0.001A
±0.5%±20dgts
±0.4%±20dgts
Range
(ACA)
Accuracy
(20Hz - 45Hz)
Accuracy
(1KHz – 10KHz)
Accuracy
(10KHz – 20KHz)
600.00 μ A
±1%±20dgts
±2%±20dgts
±1%±20dgts
6000.0 μ A
±1%±20dgts
±2%±20dgts
±1%±20dgts
60.000mA
±1%±20dgts
±0.5%±20dgts
±1%±20dgts
600.00mA
±1%±20dgts
±0.5%±20dgts
±1%±20dgts
1.0000A
±1%±20dgts
±1.5%±20dgts
Not Specified
10.000A 1
±2%±20dgts
±1.5%±20dgts
Not Specified
AC Voltage
:
The accuracy of ACV or AC mV is specified for 5%-100% of range from 20Hz – 10KHz, average sensing. Input Impedance is 10M , and overloaded protection is AC 1000V for all range. Accuracy is also specified for single channel (channel 1 or channel 2). If dual channels measurements are performed, additional specification of accuracy will be introduced. Please refer to the supplemental dual channels specification. Due to the wide bandwidth, the reading might not be zero when no inputs present. But the residual reading does not affect the listed accuracy. If the AC reading is less than 100 least significant counts, it is set to zero by the unit.
Range
(ACV)
Resolution
Accuracy
(50/60Hz)
Accuracy
(45Hz - 1KHz)
Accuracy
(20Hz - 45Hz)
60.000mV
0.001mV
±0.1%±20dgts
±0.3%±20dgts
±0.8%±25dgts
600.00mV
0.01mV
±0.1%±20dgts
±0.3%±20dgts
±0.8%±25dgts
6.0000V
0.0001V
±0.1%±20dgts
±0.3%±20dgts
±0.8%±25dgts
60.000V
0.001V
±0.1%±20dgts
±0.3%±20dgts
±0.8%±25dgts
600.00V
0.01V
±0.1%±20dgts
±0.5%±20dgts
±0.8%±25dgts
1000.0V
(0–400V)
0.1V
±0.1%±20dgts
±2%±30dgts
±0.8%±25dgts
1000.0V
(400-1000V)
0.1V
±0.1%±20dgts
(45Hz – 400Hz)
±2%±30dgts
±0.8%±25dgts
Range
(ACV)
Accuracy
1KHz–10KHz)
Accuracy
(10KHz–20KHz)
Accuracy
(20KHz-50KHz)
Accuracy
(50KHz-100KHz)
Accuracy
(100kHz-200KHz)
60.000mV
±2%±20dgts
±2.5%±20dgts
±4%±40dgts
±4%±40dgts
Not Specified
600.00mV
±1%±20dgts
±2.5%±20dgts
±2%±40dgts
±2%±40dgts
±2%±40dgts
6.0000V
±1%±20dgts
±2.0%±20dgts
±2%±40dgts
±2%±40dgts
±2%±40dgts
60.000V
±1%±20dgts
±2.0%±20dgts
±4%±40dgts
Not Specified
Not Specified
600.00V
(0-400V)
±5%±20dgts
Not Specified
Not Specified
Not Specified
Not Specified
600.00V
(400-600V)
Not Specified
Not Specified
Not Specified
Not Specified
Not Specified
1000.0V
(0-400V)
±2%±40dgts
Not Specified
Not Specified
Not Specified
Not Specified
1000.0V
(400-1000V)
Not Specified
Not Specified
Not Specified
Not Specified
Not Specified
Supplemental Dual Channels Specification (DC – 400Hz):
The following accuracy should be added to all the listed accuracy if dual channels measurements are performed.
ACV (Ch2)
DCV (Ch2)
ACA (Ch2)
DCA (Ch2)
ACV (Ch1)
±1%±( V1 - V2 ) 200 PPM (Ch1, Ch2)
±0.5%±(V1 - V2) * 20 PPM (Ch1, Ch2)
±0.1 μ A / V( μ A,Ch2)
±1 μ A / V (mA,Ch2)
±0.2mA / V (A, Ch2)
±2mV / A (mV, Ch1)
± 5mV / A (V, Ch1)
±0.25% (Ch1, Ch2)
DCV (Ch1)
±0.5%±(V1 - V2) * 20 PPM (Ch1, Ch2)
±0.25% (Ch1,Ch2
±0.25% (Ch1, Ch2)
±0.25% (Ch1, Ch2)
General Specification
Battery Type
9V
Display
5 + 5 digits LCD with 30 segments bar graph
Range Selection
auto and manual
Overload Indication
OL
Power Consumption
6 mA ( approx )
Low battery Indication
Operating Temperature
-10 C to 50 C
Operating Humidity
less than 85% relative
Altitude
up to 2000M
Storage Temperature
-20 C to 60 C
Storage Humidity
less than 75% relative
Dimension
207mm(L) x 101mm (W) x 47mm (H)8.15" (L) x 4" (W) x 1.85" (H)
Weight
430g / 15.2oz (battery included)
Accessories
Users manual x 1
RS-232C interface cable
Duty
For International Buyers
Import duties, taxes and charges are not included in the item price or shipping charges. These charges are the buyer's responsibility.
Please check with your country's customs office to determine what these additional costs will be prior to bidding/buying.
Shipping Policy
Payment Method
Returns Policy
About Feedback
Shipping Policy
● Expedited Shipping(FedEx/DHL/TNT/UPS): To USA 3-6 Workdays ,To other countries 3-8 Workdays
● Economy Shipping(Post/Airmail/DHL e-commerce): To USA 7-12 Workdays ,To United Kingdom & Australia 20-35 Workdays , To other countries 20-50 Workdays
● This is normal condition,but sometimes int'l delivery is highly depended on the courier company and local customs/duties
● We only accept Paypal payment.We are not able to ship to PO Boxes or APO/FPO addresses
● Please make sure to provide us with correct , precise and detailed shipping Address
● And it would be better to leave us correct phone number,so the delivery man can get in touch with you easily when your package arrive .And we wouldn't use your phone number for other purpose.
● Order will be shipped out within 1 to 3 business days upon payment received or cleared.
● If you don't receive package over 30 business workdays , please notify us.
Payment Method
● PayPal payment accepted only.
● Items will be shipped to your eBay address. Please make sure it is correct.
● Payment must be received 4 days after auction ended.
Returns Policy
● Customer satisfaction is our top goal. We believe our items are so outstanding. All products are quality checked. They are new and in good condition when shipped to our customers. We are convinced you will be happy with your Purchase.
● If product is defective or damage upon arrival, or wrong product shipped, please contact us immediately. Returns accepted within 30 workdays of delivery date and item must be in original new condition, not worn or altered in any way with attached tags & wrap. Otherwise deal is final. Return shipping must be paid by buyer.
● Please contact us first if you have any problems/questions/concerns. We will be happy to resolve any issues you may have in a cordial and friendly manner.
About Feedback
● When you satisfied with our product and services please leave us positive feedback.
● If a problem occurs, just contact us using the " Ask the seller a question" link on eBay.
● We appreciate your Postive Feedback, and will do the same in return. DO NOT leave negative feedback without first communication with us. Please allow max 3 business days for us to response .
Reviews